OpenFlow 1.3 and up all define meters within the OpenFlow protocol; however, they are an optional feature. At present, only ofsoftswitch and various hardware switch vendors support meters. Note that OVS is not included and does not support meters currently only the userspace datapath implements meters, as of v2.8.490.
ofsoftswitch is a software OpenFlow switch implementation, similar to OVS. It can be dowloaded and installed according to these instructions.
...
If running tail /var/log/syslog shows a lot of error messages from the ofdatapath process along the lines of "Message size too large" or "Dropping packets due to excessive rates" then this is likely the problem you're experiencing. The easiest way to handle it in Mininet is with a startup script, the relevant part would be something like this:
Code Block | ||
---|---|---|
| ||
nodes = net.hosts + net.switches for node in nodes: for port in node.ports: if str.format('{}', port) != 'lo': node.cmdPrint(str.format('ethtool --offload {} gro off gso off tso off', port)) |
Performance may still be a little on the flaky side but you should see some major improvements. Running Mininet natively on a RedHat server box we saw a consistent max total throughput increase from about 7-10 Mbps to 200 Mbps just from this. Metered flow rates are fairly close to the mark, though we have started to notice what looks like sampling rate errors cropping up in the iperf interval reporting.
Using meters in Floodlight
In order to use meters we first need to install one. This can be done using an ADD meter-mod message. Meters can then be modified or removed using the meter-mod MODIFY and DELETE messages, respectively. The following is an example:
Code Block | ||
---|---|---|
| ||
public class DropMeter { public static enum Cmd { ADD(0), MODIFY(1), DELETE(2); int cmd; Cmd(int code) { cmd = code; } public int getCode() { return cmd; } } protected DatapathId swId; /* Switch ID */ protected int flags, /* Meter flags */ rate, /* Meter band drop rate */ id, /* Meter ID */ burstSize; /* Burst control rate */ public DropMeter(DatapathId swId, int id, int flags, int rate, int burst) { this.swId = swId; this.flags = flags; this.rate = rate; this.id = id; this.burstSize = burst; } // ... public void write(Cmd cmd) { OFFactory meterFactory = OFFactories.getFactory(OFVersion.OF_13); OFMeterMod.Builder meterModBuilder = meterFactory.buildMeterMod() .setMeterId(id) .setCommand(cmd.getCode()); switch(cmd) { case ADD: case MODIFY: /* Create and set meter band */ OFMeterBandDrop.Builder bandBuilder = meterFactory.meterBands().buildDrop() .setRate(rate); if (this.burstSize != 0) { bandBuilder = bandBuilder.setBurstSize(this.burstSize); } OFMeterBand band = bandBuilder.build(); List<OFMeterBand> bands = new ArrayList<OFMeterBand>(); bands.add(band); /* Create meter modification message */ meterModBuilder.setMeters(bands) .setFlags(flags) .build(); break; case DELETE:; } /* Send meter modification message to switch */ IOFSwitch sw = switchService.getSwitch(swId); /* The IOFSwitchService */ sw.write(meterModBuilder.build()); } } |
After we install a meter, we can then tell packets to go to this meter by using the goto-meter instruction in a flow. Note that multiple flows can send packets to the same meter, or each flow can direct packets to individual meters – there is no prescribed mapping we need to use.
Code Block | ||
---|---|---|
| ||
List<OFInstruction> instructions = new ArrayList<OFInstruction>(); /* Meters only supported in OpenFlow 1.3 and up --> need 1.3+ factory */ OFInstructionMeter meter = myOF13Factory.instructions().buildMeter() .setMeterId(1) .build(); OFInstructionApplyActions output = myOF13Factory.actions().buildOutput() .setPort(OFPort.of(2)) .setMaxLen(0xffFFffFF) .build(); /* * Regardless of the instruction order in the flow, the switch is required * to process the meter instruction prior to any apply actions instruction. */ instructions.add(meter); instructions.add(Collections.singletonList((OFAction) output)); /* Flow will send matched packets to meter ID 1 and then possibly output on port 2 */ OFFlowAdd flowAdd = my13Factory.buildFlowAdd() /* set anything else you need, e.g. match */ .setInstructions(instructions) .build(); |
A final thing to note is that OpenFlow requires the switch evaluate the goto-meter instruction in a flow prior to any apply actions instruction. This ensures the meter can perform its prescribed task (e.g. drop packet or DSCP remark) prior to potentially sending the packet out. If a meter drops a packet, any further instructions in the flow will not be processed for that particular packet. (See pages 20 and 21 of the OpenFlow 1.3 spec for more information on instruction ordering/processing with regard to meters.)